WhatsApp Scan to start a chat with us!
The two common modern sizes of ceiling tiles in the UK include the 595mm x 595mm and the 1195mm x 595mm size. The two sizes are designed to suit grids at 600mm and 1200mm respectively. There exist also older ceilings that use imperial size tiles of 605mm x 605mm and 1210mm x 605mm. The tiles look the same but they are not interchangeable. The first step of choosing the correct size of the tile is measuring the existing tile. This guide focuses on the most common sizes of ceiling tiles and how to measure and choose the correct size and difference between the metric and imperial tiles. There is a 5mm gap because of the reason mentioned.
Most of the suspended ceiling tiles currently available in the UK are either the 595mm x 595mm (square tile) or 1195mm x 595mm (rectangular plank tile). They are made to be used on grids which are set out at 600mm and 1200mm respectively. The tile is deliberately manufactured 5mm less than the module to ensure that it drops within the grid as follows; the 595mm tile will fit into a 600mm module or a 1195mm tile will fit into.
Whenever anyone talks about tiles, they talk about tiles in ‘600 x 600’ dimensions. The truth is that the size of the tile is 595mm. This 5mm is meant for the tile to fit into the grid. If you ask for a tile of 600mm size, it won’t fit. It is therefore important that whenever you are measuring, assume the modern tile to be 595mm and not 600mm.
Older ceilings have the possibility of imperial modules in which 605 mm by 605 mm (or nominally 2 ft x 2 ft) and 1210 mm x 605 mm (2 ft x 4 ft) tiles are each 10 mm bigger than their metric equivalent, resulting in a metric tile falling down because of its looseness from the grid system and an imperial tile being too tight for the metric grid system.
It is possible to obtain imperial tiles because RCT has imperial 605mm x 605mm and 1210mm x 605mm tiles available and thus it will be possible to keep an old imperial ceiling without changing the grid. It is not recommended to put metric tile into imperial grid because it won’t fit there. You can always choose to change the grid to the modern metric system if you decide to change the whole ceiling, but if you need to make a patch repair, it is better to stick to imperial measurements.
All other requirements will be met either through cutting standard tiles to the desired shape at the perimeter or using special tiles made according to your specific modules. If you have an unusual module in your ceiling, RCT specialists will help you to determine whether it is necessary to cut standard tiles or use specially made tiles. In any case, however, in most ceilings there are only 595 mm or 1195 mm metric modules or 605 mm/1210 mm imperial equivalents.
In Britain there are two normal tile sizes, 595mm x 595mm and 1195mm x 595mm, which are manufactured for 600mm and 1200mm grid systems respectively. The tile is 5mm shorter than the module to fit inside the grid.
There is a 5mm difference because this is required for the tile to fit inside a 600mm grid module. A tile of 600mm cannot fit inside the grid; therefore, real modern tiles are 595mm.
Always remember that when you purchase tiles, you must measure the tiles themselves. Dimensions of tiles should be 605 mm x 605 mm or 1210 mm x 605 mm, which would suggest that these are imperial measurement, whereas 10mm more than metric indicates that the tiles are imperial. Imperial and metric tiles are not interchangeable.
Of course! RCT is able to offer special imperial 605mm x 605mm and 1210mm x 605mm tiles which help to recreate the same imperial ceiling without installing new grid system.
Choose the right dimensions of your ceiling from our range of Suspended Ceiling Tiles.
Confused whether your ceiling measurements are in metric or imperial? Give us your measurements or call 01939 251 450. We will review the dimensions and deliver either standard or imperial tiles. Get a Quote.
While choosing the replacement ceiling tile, you have to take into account five things regarding your existing ceiling: size, edge detail, material, performance (fire, acoustic and light reflection) and grid system. If you select everything properly, the replacement tile will simply plug into the grid, will fit existing tiles and behave the same way as they did. But if you make mistake in any of these five aspects, the tile won’t fit or won’t match. This guide covers all of these aspects, provides additional information on each of them, and explains how you can find out what you have and thus buy the tile without mistakes.
The majority of ceiling tiles are chosen as replacements, not as part of the installation of the ceiling from scratch. That means that existing ceiling, not specification, defines the parameters of selection. Prior to selection you have to find out the following features of existing tile: size, edge detail, material and location within the grid. Measuring one tile and making some pictures will help you to know almost everything. Our guide for identification of the existing tile will help you in this task; below we describe each choice separately.
In UK, there are two sizes of ceiling tiles: 595mm x 595mm and 1195mm x 595mm which fit into grids that have 600mm and 1200mm centres (the tile being 5mm less than the module so it falls down). Old ceilings could be using imperial measurements such as 605mm x 605mm or 1210mm x 605mm and these dimensions look almost the same; however, the problem is that they do not fit the metric grid and vice versa. The tile has to be measured to distinguish metric from imperial. Our ceiling tile size guide solves this issue entirely.
The edge detail dictates how the tile sits within the grid, and, in turn, affects the look of the finished ceiling. Common profiles include the following:
The edge profile must correspond to the grid you are using. Square edge tiles and tegular tiles are not interchangeable, even if they are the same size. Our guide to ceiling tile edge types explains each profile and the corresponding grid it requires.
Material determines the performance, appearance, and cost of tiles. The primary types include:
When it comes to replacing ceiling tiles, the easiest option is to stick with the same materials. However, this can cause issues with acoustics, fire performance, and installation. Check out our guide to ceiling tile materials for detailed comparisons.
Replacements should aim to provide the same level of performance as the original, especially if these characteristics are required by the building’s design or compliance. The three most important considerations are:
All of these components are closely related to other guides around fire ratings and acoustic and light reflectance matching.
The tile and grid form a complete unit. The width of the grid (15 mm or 24 mm exposed face) should correspond to the thickness of the tile edge, while the module Tiles should be installed in either 600 x 600 mm or 1200 x 600 mm modules. Where the new tile installation requires existing grid, then the tile should be of the same module as the grid already on site. For installations that involve replacement of the grid, the tiles and grid should be selected together.
Companies will also rebrand and eliminate some products (as seen when Armstrong became Zentia, and individual tiles are renamed or eliminated over time). In those cases where the actual tile called out is unavailable, find an alternative that matches it in size, edge detail, tile composition, and performance standards. In cases where a perfect match is essential, tiles that have been customized made are also available. The key point is to match the tangible qualities, not the tile name.
One of the rare suppliers of ceiling materials in the United Kingdom, RCT holds all the top brands in ceiling tiles such as Zentia (previously known as Armstrong), Knauf AMF, Ecophon, Rockfon, British Gypsum and Burgess CEP – Donn gridwork. They have been supplying ceiling materials since the 1960’s. The team will be able to suggest a tile for you, tell if it is still current or suggest an equivalent one based on your photographs and measurements of an existing tile. For larger quantities, a bulk quote gives you a guaranteed price. Every choice is covered by the detailed guides in this cluster and once you are set, the team will be able to give you the exact tile you need.
Size, shape, material, fire/acoustic/light reflectance performance, and compatibility with the existing grid system are five important parameters that will need to match with the existing ceiling in order to select the right tile. Measure the size of the existing tile and take a picture of the face, edge, and any codes before matching to a current product or an equivalent.
Common sizes include 595mm x 595mm and 1195mm x 595mm in metric grid systems (600mm and 1200mm centres). Imperial grid systems with sizes of 605mm x 605mm or 1210mm x 605mm are NOT interchangeable with metric grid systems. Make sure that you measure the tiles accurately.
Changing material is possible, but it requires a design decision since it will affect acoustic properties, fire performance, and fitting method. It is the simplest way to stay the same.
Instead of matching the product title, look at the properties and performance that resemble those of the existing tile: size, shape, edge type and performance. For an exact match, specially produced tiles are available. RCT can find the exact matches using photos and dimensions.
That could be because of different grid width or mismatching sizes: tegular tiles go only into a 24mm tegular grid, microlook tiles into a 15mm grid and imperial tiles don’t sit on metric grids. Check if your tile matches the grid.
See our wide range of replacement tiles available in our Suspended Ceiling Tiles category and separate pages for each brand.
Have trouble finding out which tile is yours? Send us photos and dimensions or give us a ring. 01939 251 450 – we will find it and check the stock. Get your quote.